Refrigerant recovery unit
Refrigerant recovery unit
(can handle 514a with a tank that can hold 400 KG The power supply 380 V /3 Ph /60 Hz)
Model:CMR123-20
Compressor displacement:20m3/h
Liquid push and pull filling speed:980kg/h(For the measured data in the solar heating plant, from the ton bottle into the system)
Liquid push-pull recovery speed :530kg/h(For the measured data in the solar heating plant, from the ton bottle into the system)
Push-pull theoretical velocity ≦2400kg/h(Internal diameter of the connection is greater than 3/4″)
Gas recovery rate (R245fa) :
≦78KG/H(Manometer pressure 1 bar)
≦34KG/H(Manometer pressure 0 bar)
≦18KG/H(Manometer pressure -0.4 bar)
≦12KG/H(Manometer pressure -0.6 bar)
≦4KG/H(Manometer pressure -0.9 bar)
Limiting vacuum -0.09 Mpa
Power:2HP
Power source :380V,3 PHASE,60HZ
Inspiratory pressure:-0.09~+0.15Mpa
Exhaust pressure :0-3bar
Inlet and outlet dimensions :3/4in 10m length of the flexible hose between the unit and the vessel
Suggestion:1. The cylinder must have 2 interfaces, gas and liquid
The refrigeration unit should also have two interfaces, a liquid phase port and a gas phase port
The liquid phase port of the unit must be at the lowest point, and the interface size of the unit is recommended not less than 3/4
Reviews